ABC: Aerial bundle cable Read more
BS 6381TQ: British Standard 6381TQ. Read more
BS 0361TQ: British Standard welding type cable produced according to BS634 PART 4. BS0361TQ is replaced by H01N2-D and H01N2-E
BX: A very common type of armored building wire in various configurations, rated at 600 volt (UL).
CANBUS CABLE : Data transmission cable that is used in CANBUS systems and building automation systems. CANBUS cable connects instruments that associated or directly connected to the host. Construction of CANBUS cable: flexible stranded copper wire conductors. FPE insulation. Insulated cores are twisted in pairs. Pairs twisted in layers. Cable core is wrapped with polyester tape. Screen of laminated aluminium foil. Tinned copper wire braiding. PVC compound outer sheath , RAL 4001 violette.
Category 5e F/UTP: Category 5e LAN type cable with Unshielded twisted pairs. Construction: Solid bare copper wire conductors. Although most common size is 24awg various sizes could be used. Polyolefin insulation. 4 cores solid green, blue,brown and orange. 4 cores same color scheme striped. Cores are twisted into pairs. 4 pairs twisted in layers. Overall screen of laminated Aluminium foil with drain wire. PVC Jacket. Read more
Category 5e UTP: Category 5e LAN type cable with Unshielded twisted pairs. Construction: Solid bare copper wire conductors. Although most common size is 24awg various sizes could be used. Polyolefin insulation. 4 cores solid green, blue,brown and orange. 4 cores same color scheme striped. Cores are twisted into pairs. 4 pairs twisted in layers. PVC Jacket. Read more.
Category 6 F/UTP: Category 6 LAN type cable with unshielded twisted pairs and overall foil screen. Construction: Solid bare copper wire conductors. Although most common size is 23awg various sizes could be used. Polyolefin insulation. 4 cores solid green, blue,brown and orange. 4 cores same color scheme striped. Cores are twisted into pairs. 4 pairs twisted in layers with polyolefin seperator. Overall screen of laminated Aluminium foil with drain wire. PVC Jacket, EN 50290-2-22 (TM52), VDE0207(YM2). Read more.
Category 6 SF/UTP: Category 6 LAN type data transmission cable. Unshielded twisted pairs with overall foil screen and braiding of tinned copper wire. Construction: Solid bare copper wire conductors. Although most common size is 23awg various sizes could be used. Polyolefin insulation with color coded according to EIA/TIA 568.B2. Cores are twisted into pairs. Pairs twisted in layers around polyolefin cross shape seperator. Overall screen of laminated Aluminium foil with drain wire. Braiding of tinned copper wire. PVC Jacket EN 50290-2-22 (TM52), VDE0207(YM2). Read more.
Category 6 UTP: Category 6 LAN type cable with unshielded twisted pairs. Construction: Solid bare copper wire conductors. Although most common size is 23awg various sizes could be used. Polyolefin insulation. 4 cores solid green, blue,brown and orange. 4 cores same color scheme striped. Cores are twisted into pairs. 4 pairs twisted in layers with polyolefin seperator. PVC Jacket. Read more.
Category 6 UTP LSZH : Category 6 LAN type data transmission cable with unshielded twisted pairs and "Low- Smoke Zero Halogen sheath". In case of fire Category 6 UTP LSZH does not emit toxic gasses. Category 6 UTP LSZH cable is used in local area networks of public buildings to save lives in case of fire. Construction: Solid bare copper wire conductors. Although most common size is 23awg various sizes could be used. Polyolefin insulation with color coded according to EIA/TIA 568.B2. Cores are twisted into pairs. Pairs twisted in layers around polyolefin based cross shape seperator. LSZH compound outer sheath, EN 50290-2-27, VDE0207(HM2). Read more.
Category 6 UTP PE: Category 6 LAN type data transmission cable with unshielded twisted pairs and PE outer sheath. Category 6 UTP PE designed to be used outdoors. Construction: Solid bare copper wire conductors. Although most common size is 23awg various sizes could be used. Polyolefin insulation with color coded according to EIA/TIA 568.B2. Cores are twisted into pairs. Pairs twisted in layers around polyolefin based cross shape seperator. PE outer sheath, EN 50290-2-24. RAL 9005 Black. Read more.
CCTV Cable : Transmission cable from camera to reciever/ recorder device. Used for analog cameras. Coaxial cable, audio and power conductors combined under one jacket. Usually coded as 2+1 , 4+1 etc. Read more.
CT100: British type Coaxial Satellite drop cable. Equivalent of RG 6 Coax. Construction: 1 mm solid copper inner conductor, 5 cell air spaced core insulation ( there are Foam PE versions available in market as well), CU overlapped foil screen, CU braiding, PVC sheath. ( UK). Read more.
CXTW: Twisted pair cord or single conductor for decorative lighting strings. UL -Flexible cord and cable marking. Read more.
CYKYLO-F: Flat power cable with flexible Cu Wire conductors PVC insulation and loose tube PVC sheathing rated 300/500 V. Read more.
CYKYLO-U: Flat power cable with Bare solid Cu Wire conductors PVC insulation and loose tube PVC sheathing rated 300/500 V. Read more.
CYY: 0,6/1kV Power cable Cu wire with PVC/PVC insulation. Equivalent of NYY cable. Read more.
CYY-F: 0,6/1kV Power cable Cu wire conductor with PVC/PVC insulation Equivalent of NYY cable with enhanced flame resistance. Read more.
E
EV: Electric Vehicle Cable. UL-Flexible Cord and cable
FLY: Unshielded single core Cable low-tension for automotive industry. Construction :Flexible Copper wire with PVC (105oC) insulation. Read more.
FLYY: Unshielded Single core cable low-tension for automotive industry. Construction :Flexible Copper wire with PVC (105oC) insulation + PVC Jacket. Read more.
H01N2-D: Single core harmonised welding cable. Very flexible Cu conductor with rubber jacket. Rated low voltage 10/100V. Designed for transmitting high currents between welding machine and electrode.Also suitable for machinery and tools , moving parts of assembly lines, conveyor and crane systems, automotive aseembly lines.Harmonised coding- Europe. Read more
H01N2-E: Single core harmonised welding cable. Ultra flexible Cu conductor with rubber jacket. Rated low voltage 10/100V. Designed for transmitting high currents between welding machine and electrode.Also suitable for machinery and tools , moving parts of assembly lines, conveyor and crane systems, automotive aseembly lines, automatic welding machines. Enhanced flexibility over H01N2-D. Read more
H03VH-H: Flat cable with divisible core flexible power cable rated 300/300 V. "Figure 8" construction. Fine copper conductor. Most common types are 2-cores. Used also as speaker cable. Read more
H03VV-F: Flexible low voltage power cable. Indoor appliance cable rated 300/300V. Construction ; Class 5 flexible fine stranded copper conductor, PVC core insulation. Cores are twisted in layers. PVC outer sheath. Read more.
H03VVH2-F: Flexible Low voltage flat cable with undivisible cores. Read more
H05BQ-F: Rubber insulated, polyurethane sheathed power cable rated 300/500V. Read more
H05GG-F: Harmonised coded flexible low-voltage power cable. Construction Class5 Fine tinned coppwer wire conductors , rubber insulated , rubber jacket.Rated 300/500 V. Read more
H05RN-F: Harmonised 300/500V rubber insulation, rubber jacket multicore cable for flexible applications. Construction: Class5 flexible copper conductors, rubber insulated cores, weather and oil resistant rubber overall sheath. Read more
H05RR-F: Harmonised 300/500V rubber insulation ,rubber jacket multicore cable for flexible applications. Replaced "NMH" cable. Construction: Class5 flexible copper conductors, rubber insulated cores, rubber overall sheath. Read more
H05V-K: Harmonised coded Flexible Single core hook-up wire. Rated 300/500V. PVC insulated Class5 Copper conductor. Read more.
H05V2-K: Harmonised coded Flexible Single core hook-up wire. Rated 300/500V. Heat resistant PVC insulated Class5 Copper conductor. Resistant up to 105oC. Read more.
H05V-R: Harmonised coded single core hook-up wire. Rated 300/500V. PVC insulated Class 2 Copper conductor. Read more.
H05V-U: Harmonised coded single core hook-up wire. Rated 300/500V. PVC insulated Class 1 Copper conductor. Up to 10 square mm. Over 10 square mm nominal cross section replaced by H05V-R. Read more.
H05V2V2-F: Harmonised coded Heat Resistant Flexible low voltage power cable Indoor appliance cable. Rated 300/500V. Class 5 flexible fine copper Conductor , PVC (90oC) / PVC (90oC) construction. Read more.
H05VV5-F: Harmonised coded version of German standard cable "YSLYÖ". Flexible low voltage power and control cable for indoor residential and industrial use. Rated 300/500V. Class 5 flexible fine copper sonductor , PVC / Oil resistant PVC sheath. construction. Read more.
H05VV-F: Flexible low voltage power cable Indoor appliance cable. Rated 300/500V. Class 5 flexible fine copper Conductor , PVC / PVC construction. Read more.
H05VVC4V5-K: Flexible measurement and control oil resistant cable for indoor applications. Construction: Fine stranded copper conductor, oil resistant PVC insulation. PVC inner sheath over stranded cores. Braided screen of tinned copper wires. Oil resistant PVC outer sheath. Read more.
H05VVH6-F: HO5VVH6-F cable also known as "elevator" cable. Harmonised coded flexible flat cable. Rated 300/500V. Suitable conveyor, escalator ,elevators and other applications that require traveling cable. Read more.
H05Z-K: Harmonised coded Flexible Single core hook-up wire. Rated 300/500V. Halogen free insulated Class5 Copper conductor. Maximum operating temperature 90oC. Read more.
H05Z1-K: Harmonised coded Flexible Single core hook-up wire. Rated 300/500V. Halogen free insulated Class5 Copper conductor. Maximum operating temperature 70oC. Read more.
H05Z-R: Harmonised coded single core hook-up wire. Rated 300/500V. LSZH compound insulated Class II Copper conductor. Maximum operating temperature 900C. Read more.
H05Z-U: Harmonised coded single core hook-up wire. Rated 300/500V. LSZH compound insulated Class I Copper conductor. Maximum operating temperature 900C. Read more.
H05Z1Z1-F: Flexible low voltage power cable low smoke fume halogen free Indoor cable. Rated 300/500V. Construction : Class 5 flexible fine stranded copper wire conductors. Halogen Free compound core insulation. Cores are twisted in layers. Outer sheath of Halogen Free compound. Read more.
H07BN4-F: Harmonised Rubber insulated , Chlorosulphonated Polyethylene sheathed flexible cable. Design voltage 450/750 V. Construction: Class5 flexible tinned copper conductors, rubber insulated cores, overall sheath. Read more.
H07BQ-F: Rubber insulated, polyurethane sheathed power cable rated 450/750V. Read more.
H07RN-F: Very fliexible copper conductor, insulated cross linked synthetic rubber and rubber sheath. Rated 450/750 Volt. Industrial tools, electrical trains, agricultural tools and plants, clear water plants. Replaced "NSH". Read more.
H07V-K: Harmonised coded Flexible Single core hook-up wire. Rated 450/750V. PVC insulated Class5 Copper conductor. Read more.
H07V2-K: Harmonised coded Flexible Single core hook-up wire. Rated 450/750V. Heat resistant PVC insulated Class5 Copper conductor. Resistant up to 105oC. Read more.
H07V-R: Harmonised coded single core hook-up wire. Rated 450/750V. PVC insulated Class 2 Copper conductor. Read more.
H07V-U: Harmonised coded single core hook-up wire. Rated 450/750V. PVC insulated Class 1 Copper conductor. Up to 10 square mm. Over 10 square mm nominal cross section replaced by H07V-R. Read more.
H07VV-F: Flexible low voltage power cable Indoor applications cable. Rated 450/750V. Class 5 flexible fine copper Conductor , PVC / PVC construction.
H07VVH6-F: HO7VVH6-F cable also known as "elevator" cable. Harmonised coded flexible flat cable. Rated 450/750V. Suitable conveyor, escalator , elevators and other applications that require traveling cable. Read more
H07Z-K: Harmonised coded Flexible Single core hook-up wire. Rated 450/750V. Halogen free insulated Class5 Copper conductor. Maximum operating temperature 90 oC. Read more
H07Z1-K: Harmonised coded Flexible Single core hook-up wire. Rated 450/750V. Halogen free insulated Class5 Copper conductor. Maximum operating temperature 70 oC. Read more
H07Z-R: Harmonised coded single core hook-up wire. Rated 450/750V. LSZH compound insulated Class 2 Copper conductor. Maximum operating temperature 90 oC. Read more
H07Z1-R: Harmonised coded single core hook-up wire. Rated 450/750V. LSZH compound insulated Class 2 Copper conductor. Maximum operating temperature 70 oC. Read more
H07Z-U: Harmonised coded single core hook-up wire. Rated 450/750V. LSZH compound insulated Class 1 Copper conductor. Maximum operating temperature 90 oC. Read more
H07Z1-U: Harmonised coded single core hook-up wire. Rated 450/750V. LSZH compound insulated Class 1 Copper conductor. Maximum operating temperature 70 oC. Read more
H07ZZ-F: Harmonised coded flexible low-voltage power cable with halogen free insulation and sheath. Rated 450/750 V. Read more
HBH: Indoor telephone wire for subscriber distribution. Solid bare copper conductors, Solid PE core insulation. Insulated pairs are twisted in layers. Spare pair is optional. HFFR compound jacket. Read more
HBH-K: Indoor telephone wire for subscriber distribution. Solid tinned copper conductors, Solid PE core insulation. Insulated pairs are twisted in layers. Spare pair is optional. HFFR compound jacket. Read more
HSLHCH-JZ: Halogen free version of "YSLYCY-JZ" cable. Flexible low voltage power and control cable for indoor residential and industrial use. Rated 300/500V. Construction: Class 5 flexible fine copper conductor , Halogen free compound insulation. Cores are insulated with black with consecutive numbers and a green/yellow earth core. Cores twisted in layers. Halogen free compound inner sheath over twisted cores. Braided tinned copper wire screen. Halogen free compound sheath. Read more
HSLHCH: Halogen free version of "YSLYCY" cable. Flexible low voltage power and control cable for indoor residential and industrial use. Rated 300/500V. Construction: Class 5 flexible fine copper conductor , Halogen free compound insulation. Cores are color-coded according to VDE 0293. Cores twisted in layers. Halogen free compound inner sheath over twisted cores. Braided tinned copper wire screen. Halogen free compound sheath. Read more
HSLH-JZ: Halogen free version of "YSLY-JZ" cable. Flexible low voltage power and control cable for indoor residential and industrial use. Rated 300/500V. Construction: Class 5 flexible fine copper conductor , Halogen free compound insulation. Cores are insulated black with consecutive numbers and a green/yellow earth core. Cores twisted in layers. Halogen free compound sheath. Read more.
HSLH: Halogen free version of "YSLY" cable. Flexible low voltage power and control cable for indoor residential and industrial use. Rated 300/500V. Construction: Class 5 flexible fine copper conductor , Halogen free compound insulation. Cores are color-coded according to VDE 0293. Cores twisted in layers. Cores twisted in layers. Halogen free compound sheath. Read more
INSTABUS EIB BUS HFFR CABLE : Connection cable for INSTABUS and EIB communication systems. INSTABUS EIB BUS HFFR CABLE is a twisted pair communication cable that connects all devices within the INSTABUS EIB networks. INSTABUS EIB BUS HFFR CABLE is used in intelligent building systems to remotely control the data transmission application such as, energy, air-conditioning, lighting, security, communications and diagnostics of breakdowns. INSTABUS EIB BUS HFFR CABLE is an halogen free cable that does not emit toxic or corrosive gasses in case of fire in order to save lives. Not suitable for outdoor installations. Construction: Class I Solid copper wire conductors. HFFR core insulation. Cores are twistedinto pairs. Pairs stranded to form quads and units. Polyester tape sprially wrapped around stranded cores. Overall screen of laminated Aluminium foil with tinned copper drain wire. Outer sheath of HFFR compound. Read more.
JE-H(st)H...Bd FE180/PH120: Communication and data transmission cable for indoor applications. Used in security and fire alarm systems. FE180 indicates functionality and signal transmission for minimum 180 minutes in case of fire. The functionality for 180 minutes means that fire alarm system, warning system, lifts with evacuation system, safety lighting, emergency lifts in hospitals etc. would be working properly to save lives in case of fire. Read more.
JE-2Y(st)CY PIMF: Digital signal transmission cable for indoor use. Construction: Soild copper wire conductors insulated with solid PE. Insulated cores are twisted into pairs. Paired cores twisted in layers.Laminated aluminium foil screen with drain wire and and fine strands tinned copper wire braiding. PVC Jacket. Read more
JHH: Halogen free version of JYY cable. Indoor telephone & data transmission wire. Class 1 (soild) bare copper wire conductors, insulated Halogen free compound. Cores are paired. Halogen free compound Jacket ( VDE ). Read more
JH(st)CH: JH(st)CH cable: Halogen free version of JY(st)CY cable. Indoor signal and data transmission wire. Class 1 (soild) bare copper wire conductors, Halogen free compound insulated . Cores are paired. Laminated aluminium foil screen with drain wire and fine strands copper wire braiding. Halogen free compound jacket . ( VDE ). Read more
JH(st)H:JH(st)H cable is Halogen free version of JY(st)Y cable. Indoor signal and data transmission wire. Class 1 (soild) bare copper wire conductors, Halogen free compound insulated . Cores are paired. Laminated aluminium foil screen with drain wire. Halogen free compound jacket . (VDE). Read more.
JY(st)CY: Indoor signal and data transmission wire. Class 1 (soild) bare copper wire conductors, PVC insulation . Cores are paired. Laminated aluminium foil screen with drain wire and fine strands tinned copper wire braiding. PVC jacket . Read more
JY(st)Y: JY(st)Y cable: Indoor signal, communication and data transmission wire. Class 1 (soild) bare copper wire conductors, insulated PVC. Cores are paired. Laminated aluminium foil screen with drain wire. PVC jacket . Read more.
JY(st)Y...Lg: Indoor signal , communication and data transmission wire. Class 1 (soild) bare copper wire conductors, insulated PVC. Cores are twisted into quads and then quads stranded to groups. Laminated Aluminium foil screen with drain wire. PVC jacket. Read more.
JYY: JYY cable :Indoor telephone & data transmission wire.Class 1 (soild) bare copper wire conductors, insulated PVC. Cores are paired. PVC Jacket ,(VDE) Read more
Li2Y(st)CH PIMF: Control and signal cable with enhanced electromagnetic screen. Indoor applications. Construction ;flexible bare copper wire insulated with Solid PE. Insulated Cores twisted into pairs. Each pair individually screened with PES tape+AL-PES foil and drain wire. Paired and screened pairs twisted in layers. Overall laminated Aluminium foil screen with tinned copper drain wire and Braiding of tinned copper wire . Halogen free flame retardent ( HFFR ) compound jacket- gray. Read more
Li2Y(st)CY ( RS485): Communication cable specially designed to use in RS485 communication systems. Indoor applications only. Construction: flexible bare copper wire insulated with Solid PE. Insulated Cores twisted into pairs. Pairs. Overall laminated Aluminium foil screen with tinned copper drain wire and Braiding of tinned copper wire . PVC jacket- gray. Read more
Li2Y(st)CY PIMF: Control and signal cable with enhanced electromagnetic screen. Indoor applications. Construction ;flexible bare copper wire insulated with Solid PE. Insulated Cores twisted into pairs. Each pair individually screened with PES tape+AL-PES foil and drain wire. Paired and screened pairs twisted in layers. Overall laminated Aluminium foil screen with tinned copper drain wire and Braiding of tinned copper wire . PVC jacket- gray. Read more
Li2Y(st)CY PIMF - (RS232, RS422): Communication cable specially designed to use in RS 232 and RS422 communication systems. Indoor applications. Construction ;flexible stranded bare copper wire insulated with Solid PE. Insulated Cores twisted into pairs. Each pair individually screened with PES tape+AL-PES foil and drain wire. Paired and screened pairs twisted in layers. Overall laminated Aluminium foil screen with tinned copper drain wire and braiding of tinned copper wire . PVC jacket- gray. Read more
Li2Y(st)H PIMF: Control and signal cable with enhanced electromagnetic screen. Indoor applications. Construction ;flexible wire + soild PE core insulation. Cores twisted into pairs. Each pair individually screened with PES tape+AL-PES foil and drain wire. Paired and screened pairs twisted in layers. Overall laminated Aluminium foil screen with tinned copper drain wire + Halogen free flame retardent ( HFFR ) compound jacket- gray. Read more
Li2Y(st)Y PIMF: Control and signal cable with enhanced electromagnetic screen. Indoor applications. Construction ;flexible wire + soild PE core insulation. Cores twisted into pairs. Each pair individually screened with PES tape+AL-PES foil and drain wire. Paired and screened pairs twisted in layers. Overall laminated Aluminium foil screen with tinned copper drain wire + PVC jacket- gray Read more
LiHCH: Halogen Free control and signal transmission cable with screen of braided tinned copper wire . For indoor applications. LiHCH cables are used to industrial electronics, instrumentation and control engineering applications, electronic devices and automation systems in public buildings and places. LiHCH is not suitable for outdoor applications. These cables with halogenfree flame retardant characteristic due to their structures are used in buildings where there is crowded places such as hotels, schools, hospitals, shopping centers etc. LiHCH have low smoke density and does not emit poisonous and corrosive gases in case of fire. Braiding screen protects the cable against electromagnetic interference. Construction ;flexible stranded copper wire conductors. HFFR compound core insulation, cores twisted in layers. Twisted cores wrapped in spiral PES tape. Braiding of tinned copper wire. HFFR compound jacket- gray (RAL 7001) . Read more.
LiHCH FE180/PH120: Control and signal transmission cable with enhanced electromagnetic screen. For indoor applications. Construction: Class 5 flexible stranded copper wire + HFFR compound core insulation, cores twisted in layers.PES tape seperator+ special fire resistant tape sprially wrapped. Braiding of tinned copper wire. HFFR compound jacket- orange. Complies with E90 system standard. FE180 indicates functionality and signal transmission for minimum 180 minutes in case of fire. The functionality for 180 minutes means that fire alarm system, warning system, lifts with evecuation system, safety lighting, emergency lifts in hospitals etc. would be working properly to save lives in case of fire. Read more.
LiHCH-TP: Halogen Free control and signal transmission cable with screen of braided tinned copper wire . For indoor applications. LIHCH-TP cables are used to industrial electronics, instrumentation and control engineering applications, electronic devices and automation systems in public buildings and places. LIHCH-TP is not suitable for outdoor applications. These cables with halogenfree flame retardant characteristic due to their structures are used in buildings where there is crowded places such as hotels, schools, hospitals, shopping centers etc. LiHCH-TP have low smoke density and does not emit poisonous and corrosive gases in case of fire. Braiding screen protects the cable against electromagnetic interference. Construction ;flexible stranded copper wire conductors. HFFR compound core insulation, cores first twisted into pairs then pairs stranded in layers. Stranded pairs wrapped in spiral PES tape. Braiding of tinned copper wire. HFFR compound jacket- gray (RAL 7001) . Read more.
LiHH-TP: Halogen free control and signal transmission cable for indoor applications. Construction ; Flexible stranded copper wire + PVC core insulation. Insulated cores paired first then pairs twisted in layers + PVC jacket- gray( RAL 7032 ). Read more
LiHH: Halogen free control and signal transmission cable for indoor applications. LiHH cables are used to industrial electronics, instrumentation and control engineering applications, electronic devices and automation systems where in public buildings and places. It is suitable for indoor application, it must not be used in outdoor applications. They have low smoke density and they don’t emit poisonous and corrosive gases in case of fire. Construction ;flexible stranded copper wire conductors. HFFR compound core insulation, cores stranded in layers. Stranded cores wrapped in spiral PES tape. HFFR compound jacket- gray (RAL 7001) . Read more.
LiHH FE180/PH120: Control and signal transmission cable. For indoor applications. Construction ;flexible wire + HFFR compound core insulation, cores twisted in layers. PES tape seperator+ special fire resistant tape sprially wrapped. HFFR compound jacket- orange. Complies with E90 system standard. FE180 indicates functionality and signal transmission for minimum 180 minutes in case of fire. The functionality for 180 minutes means that fire alarm system, warning system, lifts with evecuation system, safety lighting, emergency lifts in hospitals etc. would be working properly to save lives in case of fire. Read more
LiH(st)CH: Control and signal transmission cable with enhanced electromagnetic screen. LiH(st)CH cable used for industrial electronics, instrumentation and control engineering applications, indoor voice systems, security systems, electronic devices and automation systems. It is suitable for only indoor applications. Braided copper screen protects the cable against electromagnetic interference. These cables with halogenfree flame retardant characteristic due to their structures are used in public buildings such as hotels, schools, hospitals, shopping centers etc. LiH(st)CH cable have low smoke density and does not emit toxic or corrosive gases in case of fire. Construction ;Class 5 flexible stranded copper wire conductors. HFFR compound core insulation. Cores are twisted in layers. Screen of Polyester laminated Aluminium foil with tinned copper drain wire. Braiding of tinned copper wire. HFFR compound jacket- gray. Read more.
LiH(st)CH-TP: Control and signal transmission cable with enhanced electromagnetic screen. For indoor applications. Construction ;flexible stranded copper wire + HFFR compound core insulation. Insulated cores paired first then pairs twisted in layers + Aluminium PES foil screen + Braiding of tinned copper wire + HFFR compound jacket- gray. Read more
LiH(st)CH FE180/PH120: Control and signal transmission cable with enhanced electromagnetic screen. For indoor applications. Construction ; Class 5 flexible stranded copper wire conductors. Cross linked special compound core insulation, cores twisted in layers. PES tape seperator and special fire resistant tape sprially applicated with tinned copper drain wire over twisted cores. Aluminium-PES foil static screen. Braiding of tinned copper wire. Outer sheath of HFFR ( halogen free flame retardent ) compound, orange. Complies with E90 system standard. FE180 indicates functionality and signal transmission for minimum 180 minutes in case of fire. The functionality for 180 minutes means that fire alarm system, warning system, lifts with evecuation system, safety lighting, emergency lifts in hospitals etc. would be working properly to save lives in case of fire. Read more.
LiH(st)CH PIMF: Control and signal cable with enhanced electromagnetic screen. Indoor applications. Construction ;flexible stranded copper wire conductors. Halogen free flame retardent core insulation. Cores twisted into pairs. Each pair individually screened with PES tape+AL-PES foil and drain wire. Paired and screened pairs twisted in layers. Overall laminated Aluminium foil screen with tinned copper drain wire and Braiding of tinned copper wire . HFFR compound jacket- gray. Read more.
LiH(st)H: Control and signal cable with enhanced electromagnetic screen. Indoor applications. Construction ;flexible stranded copper wire, HFFR compound core insulation. Cores twisted in layers. Laminated Aluminium foil screen. HFFR compound jacket- gray. Read more.
LiH(st)H FE180/PH120: Control and signal transmission cable with enhanced electromagnetic screen. For indoor applications. Construction ;flexible wire + HFFR compound core insulation, cores twisted in layers.PES tape seperator+ special fire resistant tape sprially wrapped. Aluminium-PES foil screen . HFFR compound jacket- orange. Complies with E90 system standard. FE180 indicates functionality and signal transmission for minimum 180 minutes in case of fire. The functionality for 180 minutes means that fire alarm system, warning system, lifts with evecuation system, safety lighting, emergency lifts in hospitals etc. would be working properly to save lives in case of fire. Read more.
LiH(st)H-TP: Control and signal transmission cable with enhanced electromagnetic screen. Indoor applications. Construction ;flexible stranded copper wire + HFFR compound core insulation. Insulated cores paired first then pairs twisted in layers + Laminated Aluminium foil screen (AL-PES) + HFFR compound jacket- gray. Read more.
LiH(st)H PIMF: Control and signal cable with enhanced electromagnetic screen. Indoor applications. Construction ;flexible stranded copper wire conductors. Halogen free compound core insulation. Cores twisted into pairs. Each pair individually screened with PES tape+AL-PES foil and drain wire. Paired and screened pairs twisted in layers. Overall laminated Aluminium foil screen with tinned copper drain wire +Halogen free flame retardent ( HFFR ) compound jacket- gray. Read more.
LiYC2Y: Control and signal cable with braided screen of fine copper wire . For outdoor applications. Construction ;flexible stranded copper wire conductors + PVC core insulation, cores twisted in layers + Cable core wrapped in spiral PES tape + Braiding of tinned copper wire + PE jacket- black. Read more.
LiYCY: Control and signal cable with screen of braided fine copper wire . For indoor applications. Construction ;flexible stranded copper wire conductors + PVC core insulation, cores twisted in layers + Cable core wrapped in spiral PES tape + Braiding of tinned copper wire + PVC jacket- gray . Read more.
LIYCY-CY: Control and signal cable double braiding screen. LIYCY-CY cable is used in industrial electronic, instrumentation and control engineering applications, sound studios, building inside sound systems, communication systems, security systems and electronic devices. It is suitable for indoor applications but not suitable for outdoor applications. Each pair is individually screened with fine tinned copper braiding and sheathed. LIYCY-CY has general braiding screen underneath overall sheathing to create protection against to electromagnetical interference. Read more.
LIYCY-TP: Control and signal cable
with screen of braided fine copper wire . Suitable for indoor applications.
LiYCY-TP is considered as flexible wire. it could be easily used in
many applications. LiYCY-TP cables are used to industrial electronics,
instrumentation and control engineering applications, electronic devices and
automation systems. Braided screen protects the cable against
electromagnetic interference. Construction ; flexible stranded copper wire conductors. PVC core insulation
color coded according to DIN47100.
Insulated cores paired first then pairs stranded in layers. Cable core
wrapped in spiral PES
tape. Braiding of tinned copper wire. PVC jacket- gray.
Read more.
LiY(st)CY: Control and signal transmission cable with
enhanced electromagnetic screen. Suitable for indoor applications. LiY(st)CY
cable can easily be used in flexible applications. These cables are used to
industrial electronics, instrumentation and control engineering
applications, indoor voice systems, security systems, electronic devices and
automation systems. The braid screen protects the cable against
electromagnetic interference. Class 5 flexible stranded copper wire
conductors. PVC core insulation. Cores are twisted in layers. Screen of
Polyester laminated Aluminium foil with tinned copper drain wire. Braiding
of tinned copper wire. PVC jacket- gray.
Read more.
LiY(st)CY-TP: Control and signal
transmission cable with enhanced electromagnetic screen. For indoor
applications. Construction: flexible wire + PVC core insulation.
Insulated cores paired first then pairs twisted in layers + Aluminium PES
foil screen + Braiding of tinned copper wire + PVC jacket- gray.
Read more.
LiY(st)CY PIMF: Control and signal cable
with enhanced electromagnetic screen. Indoor applications.
Construction ;flexible wire + PVC core insulation. Cores twisted into pairs.
Each pair individually screened with PES tape+AL-PES foil and drain wire.
Paired and screened pairs twisted in layers. Overall laminated Aluminium foil screen
with tinned copper drain wire and Braiding of tinned copper wire . PVC jacket- gray.
Read more.
LiY(st)Y: Control and signal cable
with enhanced electromagnetic screen. Indoor applications.
Construction ;flexible wire + PVC core insulation. Cores twisted in layers +
Laminated Aluminium foil screen + PVC jacket- gray.
Read more.
LiY(st)Y-TP: Control and signal
transmission cable with enhanced electromagnetic screen. Indoor
applications. Construction ;flexible wire + PVC core insulation.
Insulated cores paired first then pairs twisted in layers + Laminated Aluminium foil screen
( AL-PES) + PVC jacket- gray. Read more.
LiY(st)Y PIMF: Control and signal cable
with enhanced electromagnetic screen. Indoor applications.
Construction ;flexible wire + PVC core insulation. Cores twisted into pairs.
Each pair individually screened with PES tape+AL-PES foil and drain wire.
Paired and screened pairs twisted in layers. Overall laminated Aluminium foil screen
with tinned copper drain wire + PVC jacket- gray.
Read more.
LiYY: Control
and signal transmission cable for indoor applications. LiYY cable
could be used in many different applications. These cables are used to
industrial electronics, instrumentation and control engineering
applications, electronic devices and automation systems. Construction:
Flexible stranded copper wire. PVC core insulation. Cores twisted in
layers. PVC jacket. Read more.
LiYY-TP: Control and signal
transmission cable for indoor applications. Construction: Flexible
stranded copper wire + PVC core insulation. Insulated cores paired first
then pairs twisted in layers + PVC jacket- gray( RAL 7032 ).
Read more.
N2XH: 0,6/1kV Power cable ,Crosslinked insulation with halogen free sheathed cable
N2XY: 0,6/1kV Power cable ,Crosslinked insulation with PVC sheathed cable
(N)HMH: Halogen Free Flame resistant power cable.
"N" indicates that this cable is according to VDE standard.
NHSLHCH: Halogen free version of "NYSLYCY" cable. Flexible low voltage power and control cable
for indoor residential and industrial use. Rated 300/500V.
Construction: Class 5 flexible
fine copper conductor , Halogen free compound insulation. Cores
twisted in layers. Halogen free compound inner sheath over twisted cores.
Braided tinned copper wire screen. Halogen free compound sheath. "N"
indicates that this cable is according to VDE standard
NHSLH: Halogen free version of "NYSLY" cable. Flexible low voltage power and control cable
for indoor residential and industrial use. Rated 300/500V.
Construction: Class 5 flexible
fine copper conductor , Halogen free compound insulation. Cores
twisted in layers. Halogen free compound sheath. "N" indicates that
this cable is according to VDE standard
NHXMH: Halogen Free Flame resistant power cable-cross linked insulation.
Rated 300/5000 V. "N" indicates that this cable is according to VDE standard
NMH: Flexible multi core Class 5 copper conductors rubber insulated and sheathed
power cable . Rated 300/500 V. Replaced by H05RR-F in Harmonised coding.
"N" indicates that this cable is according to VDE standard.
NYAFZ: Equivalent of H03VH-H cable.
"N" indicates that this cable is according to VDE standard.
NYIFY: Flat indoor power cable
rated 300/300V
NYM:
Copper conductor PVC insulated PVC sheathed power cable rated 450/750V.
"N" indicates that this cable is according to VDE standard.
NYSLY-Ö: Equivalent
of "H05VV5-F". Flexible low voltage power and control cable for indoor
residential and industrial use. Rated 300/500V. Class 5 flexible
fine copper wire conductor , PVC core insulation / Oil resistant PVC sheath.
"N" indicates that this cable is according to VDE standard.
Read more.
NYSLYCY: Flexible low voltage power and control cable for indoor residential and industrial use. Rated 300/500V. Construction: Class 5 flexible fine copper conductor , oil resistant PVC. Cores twisted in layers. PVC compound inner sheath over twisted cores. Braided tinned copper wire screen. Oil resistant PVC sheath- Gray. "N" indicates that this cable is according to VDE standard
NYSLYQY: Flexible low voltage power and control cable for industrial use in instrumentation and control Engineering, Fuel Oil Pumps, machinery assembly and production and Assembly Lines. Rated 300/500V. Construction: Class 5 flexible fine copper conductor , insulated PVC. Cores twisted in layers. PVC compound inner sheath over twisted cores. Braided galvenized steel wire armour. Oil resistant PVC outer sheath. "N" indicates that this cable is according to VDE standard.
NYY: 0,6/1kV Cu Conductor ,PVC insulated PVC sheathed direct burial power cable."N" indicates that this cable is according to VDE standard.
PAP: Direct burial telephone cable with Copper wire conductors , PE core insulation, corrugated aluminum shield, PE jacket. Black jacket color. Various types available.
PD-PAP: Direct burial , outdoor Telephone wire with solid copper conductors, PE core
insulation, PE inner sheath , Laminated aluminium foil screen , Black PE
jacket.
PDV: Indoor
telephone wire for subscriber distribution. Solid bare copper conductors,
Solid PE core insulation. Insulated pairs are twisted in layers. Spare pair
is optional.
PVC jacket.
PDV-K: Indoor
telephone wire for subscriber distribution. Solid tinned copper conductors,
Solid PE core insulation. Insulated pairs are twisted in layers. Spare pair
is optional.
PVC jacket.
PLSJ: Rubber insulated, parallel-jacketed, two-conductor, light duty cord for
pendent or portable use in damp locations. Rated 300V.
PLT: Thermoplastic insulated, parallel-jacketed, two-conductor, light duty cord
for pendent or portable use in damp locations. Rated 300V.
Profibus L2: Control and Data transmission cable in Profibus systems for control and measurement purposes. Profibus L2
cable is used in multiple devices where system control is provided by
transmitting high-speed data from a single center. Suitable for only indoor
applications. Construction: AWG22
solid bare copper wire conductors. Foam skin PE core insulation
according to EN 50290-2-23, VDE0207. Cores twited into pairs. Pairs stranded
in layers. PES sperator tape. PES laminated Aluminium foil screen
with tinned copper wire drain. Braided screen of tinned copper wire. PVC
jacket according to EN 50290-2-22 (TM52), VDE0207(YM2). RAL 4001 Violet.
RE-2X(ST)H: RE-2X(st)H is XLPE insulated and Halogen free compound sheathed communication and instrumentation cable produced according to BS EN 50288. RE-2X(st)H cables are multi-core metallic cables designed for analogue or digital signal transmission in instrumentation, analogue and digital communication, process control applications for monitoring and measurement. RE-2X(st)H is used in oil plants, gas stations, petrochemical and power generation industries and thermal power plants. In case of fire RE-2X(st)H cable does not emit halgoen or any other toxic gas that may be harmful to human life. Maximum operating temperature for fixed installations is 700C degrees. Rated 300V.
RE-2X(ST)Y-fl: RE-2X(st)Y-fl is XLPE insulated and PVC sheathed communication and instrumentation cable produced according to BS EN 50288. RE-2X(st)Y-fl cables are multi-core metallic cables designed for analogue or digital signal transmission in instrumentation, analogue and digital communication, process control applications for monitoring and measurement. RE-2X(st)Y-fl is used in oil plants, gas stations, petrochemical and power generation industries and thermal power plants. Maximum operating temperature for fixed installations is 700C degrees. Rated 300V. Insulation resistance is >5000MΩxkm
RE-2Y(ST)Y-fl: RE-2Y(st)Y-fl is PE insulated and PVC sheathed communication and instrumentation cable produced according to BS EN 50288-7. RE-2Y(st)Y-fl cables are multi-core metallic cables designed for analogue or digital signal transmission in instrumentation, analogue and digital communication, process control applications for monitoring and measurement. RE-2Y(st)Y-fl is used in oil plants, gas stations, petrochemical and power generation industries and thermal power plants. Maximum operating temperature for fixed installations is 750C degrees. Rated 300V.
RE-T2X(ST)H: RE-T2X(st)H is a mica tape applicated ,XLPE insulated and Halogen free compound sheathed communication and instrumentation cable produced according to BS EN 50288-7. RE-T2X(st)H cables are multi-core metallic cables designed for analogue or digital signal transmission in instrumentation and communication, process control applications for monitoring and measurement. RE-T2X(st)H is used in oil plants, gas stations, petrochemical and power generation industries and thermal power plants. No direct burial. RE-T2X(st)H is used in applications where circuit integrity is required in the event of fire. In case of fire. RE-T2X(st)H cable does not emit halgoen or any other toxic gas that may be harmful to human life. Maximum operating temperature for fixed installations is 900C degrees.
RE-Y(ST)Y-fl: RE-Y(st)Y-fl is PVC insulated and PVC sheathed
communication and instrumentation cable produced according to BS EN 50288-7.
RE-Y(st)Y-fl cables are multi-core metallic cables designed for analogue or
digital signal transmission in instrumentation, analogue and digital
communication, process control applications for monitoring and measurement.
RE-Y(st)Y-fl is used in oil plants, petrochemical and power generation
industries and thermal power plants. Maximum operating temperature is 750C
degrees. Rated 300V.
RG 11/ U : Main distribution cable for CATV , CCTV, MATV and satellite antenna systems. Common construction: solid copper conductor, Foam PE dielectric insulation. Laminated metal foil screen with metal braiding , PVC, LDPE or HFFR compound jacket. Various types are also avaiable depending of application and enviroment conditions.Impedance: 75 Ω
RG 11/ U-4: Main distribution cable for CATV , CCTV, MATV and satellite antenna systems. Common construction: solid copper conductor diameter 1.63mm, Foam PE dielectric insulation. Laminated Aluminium foil screen with tinned copper braiding. PVC Jacket for indoor applications. , LDPE for outdoor usage. Impedance: 75 Ω
RG 11/ U-4 CCS: Main distribution cable for CATV , CCTV, MATV and satellite antenna systems. Common construction: CCS conductor diameter 1.63mm, Foam PE dielectric insulation. Laminated Aluminium foil screen with tinned copper braiding. PVC Jacket for indoor applications. , LDPE for outdoor usage. Impedance: 75 Ω
RG 11/ U-4 CCS HF: Main distribution cable for CATV , CCTV, MATV and satellite antenna systems. Common construction: CCS conductor diameter 1.63mm, Foam PE dielectric insulation. Laminated Aluminium foil screen with tinned copper braiding. HFFR compound jacket indoor installations with safety concerns. Impedance: 75 Ω
RG 11/ U-4 HF: Main distribution cable for CATV , CCTV, MATV and satellite antenna systems. Common construction: solid copper conductor diameter 1.63mm, Foam PE dielectric insulation. Laminated Aluminium foil screen with tinned copper braiding. HFFR compound jacket indoor installations with safety concerns. Impedance: 75 Ω
RG 11/ U-4 PE: Main distribution cable for CATV , CCTV, MATV and satellite antenna systems. Common construction: solid copper conductor diameter 1.63mm, Foam PE dielectric insulation. Laminated Aluminium foil screen with tinned copper braiding. LDPE for outdoor usage. Impedance: 75 Ω.
RG 11/ U-6: Main distribution cable for CATV , CCTV, MATV and satellite antenna systems. Common construction: solid copper conductor diameter 1.63mm, Foam PE dielectric insulation. Laminated copper foil screen with annelead copper braiding. PVC jacket for indoor applications. Impedance: 75 Ω
RG 11/ U-6 CCS: Main distribution cable for CATV , CCTV, MATV and satellite antenna systems. Common construction: solid CCS conductor diameter 1.63mm, Foam PE dielectric insulation. Laminated copper foil screen with annelead copper braiding. PVC jacket for indoor applications. Impedance: 75 Ω
RG 11/ U-6 HF: Main distribution cable for CATV , CCTV, MATV and satellite antenna systems. Common construction: solid copper conductor diameter 1.63mm, Foam PE dielectric insulation. Laminated copper foil screen with annelead copper braiding. HFFR compound jacket. Indoor installations only with safety concerns in case of fire. Impedance: 75 Ω
RG 11/ U-6 CCS HF: Main distribution cable for CATV , CCTV, MATV and satellite antenna systems. Common construction: solid CCS conductor diameter 1.63mm, Foam PE dielectric insulation. Laminated copper foil screen with annelead copper braiding. HFFR compound jacket. Indoor installations only with safety concerns in case of fire. Impedance: 75 Ω
RG 11/ U-6 PE: Main distribution cable for CATV , CCTV, MATV and satellite antenna systems. Common construction: solid copper wire conductor diameter 1.63mm, Foam PE dielectric insulation. Laminated copper foil screen with annelead copper braiding. LDPE jacket for outdoor use. Impedance: 75 Ω
RG 213/ U: 50 Ω coaxial flexible connection cable for Medicine , measuring devices , military applications, etc. Commercial grade and Mil spec versions may have slight difference. Common construction : stranded analead copper conductor , Solid PE insulation , Braiding of fine copper strands, PVC Jacket-Black
RG59 U: 75 Ω Coaxial cable as hook-up wire for CATV, CCTV, SATV systems. Common construction : Solid copper wire 0,80mm diameter inner conductor size. Cellular PE core insulation. Various screen and jacket versions avaiable.
RG59 U-4: 75 Ω Coaxial cable as hook-up wire for CATV, CCTV, SATV systems. Common construction : Solid copper wire 0,80mm diameter inner conductor size. Cellular PE core insulation. Laminated Aluminium foil screen with tinned copper braiding. PVC jacket for indoor applications.
RG59 U-4 CCS: 75 Ω Coaxial cable as hook-up wire for CATV, CCTV, SATV systems. Common construction : Solid CCS wire 0,80mm diameter inner conductor size. Cellular PE core insulation. Laminated Aluminium foil screen with tinned copper braiding. PVC jacket for indoor applications.
RG59 U-4 CCS HF: 75 Ω Coaxial cable as hook-up wire for CATV, CCTV, SATV systems. Common construction : Solid CCS wire 0,80mm in diameter inner conductor size. Cellular PE core insulation. Laminated Aluminium foil screen with tinned copper braiding. HFFR compound jacket. Indoor installations only with safety concerns in case of fire.
RG59 U-4 HF: 75 Ω Coaxial cable as hook-up wire for CATV, CCTV, SATV systems. Common construction : Solid copper wire 0,80mm diameter inner conductor size. Cellular PE core insulation. Laminated Aluminium foil screen with tinned copper braiding. HFFR compound jacket. Indoor installations only with safety concerns in case of fire.
RG59 U-6: 75 Ω Coaxial cable as hook-up wire for CATV, CCTV, SATV systems. Common construction : Solid copper wire 0,80mm diameter inner conductor size. Cellular PE core insulation. Laminated copper foil screen with annelead copper braiding. PVC jacket for indoor applications.
RG59 U-6 CCS: 75Ω Coaxial cable as hook-up wire for CATV, CCTV, SATV systems. Common construction : Solid CCS wire 0,80mm diameter inner conductor size. Cellular PE core insulation. Laminated copper foil screen with annelead Copper or CCA wire braiding. PVC jacket for indoor applications.
RG59 U-6 CCS HF: 75 Ω Coaxial cable as hook-up wire for CATV, CCTV, SATV systems. Common construction : Solid CCS wire 0,80mm diameter inner conductor size. Cellular PE core insulation. Laminated copper foil screen with annelead copper braiding. HFFR compound jacket. Indoor installations only with safety concerns in case of fire.
RG59 U-6 HF: 75 Ω Coaxial cable as hook-up wire for CATV, CCTV, SATV systems. Common construction : Solid copper wire 0,80mm diameter inner conductor size. Cellular PE core insulation. Laminated copper foil screen with annelead copper braiding. HFFR compound jacket. Indoor installations only with safety concerns in case of fire.
RG6 U-4: 75 Ω Coaxial cable as distribution and drop wire for CATV, CCTV, SATV systems. Common construction : Solid copper wire 1,02mm inner conductor size. Cellular PE core insulation. Laminated Aluminium foil screen with tinned copper wire braiding. PVC jacket, for indoor applications only.
RG6 U-4 CCS: 75 Ω Coaxial cable as distribution and drop wire for CATV, CCTV, SATV systems. Common construction : Solid CCS wire 1,02mm inner conductor size. Cellular PE core insulation. Laminated Aluminium foil screen with tinned copper wire braiding. PVC jacket, for indoor applications only.
RG6 U-4 CCS HF: 75 Ω Coaxial cable as distribution and drop wire for CATV, CCTV, SATV systems. Common construction : Solid CCS wire 1,02mm inner conductor size. Cellular PE core insulation. Laminated Aluminium foil screen with tinned copper wire braiding. HFFR compound jacket, indoor installations with security concerns in case of fire.
RG6 U-4 HF: 75 Ω Coaxial cable as distribution and drop wire for CATV, CCTV, SATV systems. Common construction : Solid copper wire 1,02mm inner conductor size. Cellular PE core insulation. Laminated Aluminium foil screen with tinned copper wire braiding. HFFR compound jacket, indoor installations with security concerns in case of fire.
RG6 U-6: 75 Ω Coaxial cable as distribution and drop wire for CATV, CCTV, SATV systems. Common construction : Solid copper wire 1,02mm inner conductor size. Cellular PE core insulation. Laminated copper foil screen with bare copper wire braiding. PVC jacket for indoor applications only. Read more.
RG6 U-6 CCS: 75 Ω Coaxial cable as distribution and drop wire for CATV, CCTV, SATV systems. Common construction : Solid CCS wire 1,02mm inner conductor size. Cellular PE core insulation. Laminated copper foil screen with bare copper wire braiding. PVC jacket for indoor applications only.
RG6 U-6 CCS HF: 75 Ω Coaxial cable as distribution and drop wire for CATV, CCTV, SATV systems. Common construction : Solid CCS wire 1,02mm inner conductor size. Cellular PE core insulation. Laminated copper foil screen with bare copper wire braiding. HFFR compound jacket, indoor installations with security concerns in case of fire.
RG6 U-6 HF: 75 Ω Coaxial cable as distribution and drop wire for CATV, CCTV, SATV systems. Common construction : Solid copper wire 1,02mm inner conductor size. Cellular PE core insulation. Laminated copper foil screen with bare copper wire braiding. HFFR compound jacket, indoor installations with security concerns in case of fire.
RG6 Trishield: 75 Ω drop cable for CATV, CCTV, SATV systems. Common construction : Solid 1,02mm inner conductor size. Cellular PE core insulation. Laminated copper foil screen with bare copper wire braiding. Additional Laminated copper foil screen underneath PVC jacket.
RHRW: Tinned copper conductors, rubber insulation, saturated braid, flame and moisture resistant finish for moist locations.
RHW: 75° C rubber insulated. Heat and moisture resistant insulation with an outer cover of moisture resistant, flame-retardant and a nonmetallic covering. Generally used in wet locations.
SJ: SJ cable is used in portable tools and equipment, portable appliances, small motors, and associated machinery. Flexible stranded copper wire conductors according to ASTM B-174. Rubber insulation and rubber jacket. Rated 300 V. ( UL )
SJO: SJO stands for Junior service cord oil resistant. SJO cable (cord) is used in portable tools and equipment, portable appliances, small motors, and associated machinery. Flexible stranded copper wire conductors according to ASTM B-174. Rubber insulation and Neoprene® jacket. Neoprene® is a trademark of the DuPont de Nemours Co. (UL )
SJTO: SJT stands for Junior service cord Thermoplastic insulation( most common PVC ) . SJT cable (cord) is used in heavy tools, equipment, portable lights, and power extensions. Approved for outdoor use. Flexible stranded copper wire conductors according to ASTM B-174. Cores are PVC insulated and PVC jacket. Maximum operating temperature 105oC. Rated 300V.
SP-1: Lamp cord, All rubber, parallel-jacketed, two-conductor, light duty cord for pendant or portable use. 300 V. Insulation thickness 0,030 inches.(UL).
SP-2: Similar to SP-1 with insulation thickness 0,045 inches. Used for household appliances. Rated 300 V. (UL).
SP-3: Similar to SP-1 with insulation thickness between 0,06 to 0,11 inches . Used for refrigerators or room air conditioners. It also may have a third conductor for grounding purposes. Rated 300 V ( UL ).
SPT-1 : Lamp cord, PVC Insulated, parallel-jacketed, two-conductor, light duty cord for pendant or portable use. With or without a third core fro grounding puposes.300 V. Insulation thickness 0,030 inches.
SPT-2: Lamp cord, PVC Insulated, parallel-jacketed, two-conductor, light duty cord for pendant or portable use. With or without a third core fro grounding puposes.300 V. Insulation thickness 0,045 inches.
SPT-3: Lamp cord, PVC Insulated, parallel-jacketed, two-conductor, light duty cord for pendant or portable use. With or without a third core fro grounding puposes.300 V. Insulation thickness 0,060 to 0,11 inches.
ST: ST stands for Service cord Thermoplastic insulation( most common PVC ) . ST cable (cord) is used in heavy tools, equipment, portable lights, and power extensions. Approved for outdoor use. Flexible stranded copper wire conductors according to ASTM B-174. Cores are PVC insulated and PVC jacket. Maximum operating temperature 1050C. Rated 600V
SV: Not hard usage Flexible Cord. UL -Flexible cord and cable marking.
SV: Vacuum cleaner cord. Stranded tinned copper conductors. Rubber insulation and jacket.Rated 300 volt.
SVO: Vacuum cleaner cord. Stranded tinned copper conductors. Rubber insulation and oil resistant rubber jacket. Rated 300 volt.
SVT: Vacuum cleaner cord. Stranded tinned copper conductors. PVC insulation and jacket.Rated 300 volt.
THINNET: Thin coaxial cable used for 10Base2 installations of Ethernet networking. Thinnet cable is RG58 type coaxial cable that has 50 ohms impedance value.
THW: Single conductor building wire, thermoplastic insulated, heat, flame, and moisture resistant, 75° C. Used in feeder and branch circuits, and internal secondary industrial distribution.
THWN: Single conductor building wire, thermoplastic insulated, with Nylon overall jacket. Heat, flame, and moisture resistant, 75° C. Used for installation in conduit, machine tools, controlled circuits, or other general purpose wiring. Used in dry and wet locations.
TW: The UL designation for thermoplastic insulated wire for use in conduit, underground, and wet locations. It is a common building wire having a bare soft copper conductor, which may be either solid or stranded.
VBAPV: VBAPV is indoor telephone wire for residential and commercial buildings. VBAPV cable is used for signal transmission and subscriber connection. VBAPV Cable is protected from electromagnetic interference by screen of AL-PES foil and tinned copper drain wire. Construction : Solid bare copper wire conductors. PVC core insulation. Cores are twisted into pairs. Pairs twisted in layers. PVC outer sheat- Gray.
VBAPV-K: VBAPV-K is indoor telephone wire for residential and commercial buildings. VBAPV-K cable is used for signal transmission and subscriber connection. It is protected from electromagnetic interference by screen of AL-PES foil and tinned copper drain wire. Since VBAPV-K has tinned copper wire conductors , it is suitable to be installed damp places. Construction : Solid tined copper wire conductors. PVC core insulation. Cores are twisted into pairs. Pairs twisted in layers. PVC outer sheat- Gray.
VBV: VBV is indoor telephone wire for residential and commercial buildings. VBV cable is used for signal transmission and subscriber connection. Construction : Solid bare copper wire conductors. PVC core insulation. Cores are twisted into pairs. Pairs twisted in layers. PVC outer sheat- Gray.
VBV-K: VBV-K is indoor telephone wire for residential and commercial buildings. VBV-K cable is used for signal transmission and subscriber connection. Since VBV-K has tinned copper wire conductors , it is suitable to be installed damp places. Construction : Solid tined copper wire conductors. PVC core insulation. Cores are twisted into pairs. Pairs twisted in layers. PVC outer sheat- Gray.
VTLmB: Equivalent of H03VH-H cable
XHHW: XHHW stands for Cross-linked High Heat resistant, water resistant. Aluminium or Copper stranded conductors. Cross-linked polyethylene insulation. Max operating temperature 90° C in dry locations and 75° C in wet locations. Rated 600V. Sizes "2 AWG" and larger are sunlight resistant.
XTW: Parallel cord for decorative lighting strings. UL -Flexible cord and cable marking.
YSLYCY: Flexible low voltage power and control cable for indoor residential and industrial use. Rated 300/500V. Construction: Class 5 flexible fine copper conductor , oil resistant PVC core insulation. Cores are color soded according to VDE0293. Insulated cores twisted in layers. PVC compound inner sheath over twisted cores. Braided tinned copper wire screen. Oil resistant PVC sheath- Gray.
YSLYCY-JZ: Flexible low voltage power and control cable for indoor residential and industrial use. Rated 300/500V. Construction: Class 5 flexible fine copper conductor , oil resistant PVC. Cores are insulated with black with consecutive numbers and a green/yellow earth core. Isulated cores twisted in layers. PVC compound inner sheath over twisted cores. Braided tinned copper wire screen. Oil resistant PVC sheath- Gray.
YSLY: Flexible low voltage power and control cable for indoor residential and industrial use. Rated 300/500V. Class 5 flexible fine copper wire conductor , PVC core insulation. Cores are color soded according to VDE0293. Insulated cores twisted in layers. PVC sheath- GRAY.
YSLY-JZ: Flexible low voltage power and control cable for indoor residential and industrial use. Rated 300/500V. Class 5 flexible fine copper wire conductor , PVC core insulation. Cores are insulated with black with consecutive numbers and a green/yellow earth core. Cores twisted in layers. PVC sheath- GRAY.
YSLYÖ: Equivalent of "H05VV5-F". Flexible low voltage power and control cable for indoor residential and industrial use. Rated 300/500V. Class 5 flexible fine copper wire conductor , PVC core insulation / Oil resistant PVC sheath.
YSLYQY: Flexible low voltage power and control cable for industrial use in instrumentation and control Engineering, Fuel Oil Pumps, machinery assembly and production and Assembly Lines. Rated 300/500V. Construction: Class 5 flexible fine copper conductor , insulated PVC. Cores twisted in layers. PVC compound inner sheath over twisted cores. Braided galvenized steel wire armour. Oil resistant PVC outer sheath.
YVV: Direct Burial underground cable. Bare Copper conductor/ PVC insulation/PVC sheath construction. Rated 0,6/1kV. Equivalent of "NYY" cable.
YZwL: German equivalent of harmonised H03VH-H cable. Flat Divisible flexible power cable rated 300/300 V. "Figure 8" construction. Very flexible fine stranded copper conductor. Most common types are 2-cores. Used also as speaker cable.
11YSL11YC11Y: Flexible, TPU insulated and TPU ( Thermoplastic Polyurethane ) sheathed instrumentation and low voltage power cable. Produced according to VDE. 11YSL11YC11Y cable is used in instrument and control engineering, dry, moisture, oil, oil derivatives and acidic environments in machine lines due to its flexibility and low bending radius. Its braiding screen creates protection against electromagnetical effects while inner sheath of TPU creates extra protection for chemicals. Construction of 11YSL11YC11Y cable: Class 5 copper wire conductors insulated with TPU. Cores are twisted in layers. Inner sheath of TPU over twisted cores. Braiding of tinned copper wire. TPU jacket. RAL 7001 gray.
11YSLC11Y: Flexible, TPU insulated and TPU
( Thermoplastic Polyurethane ) sheathed instrumentation and low voltage power
cable. Produced according to VDE. 11YSLC11Y cable is used in instrument and
control engineering, dry, moisture, oil, oil derivatives and acidic environments
in machine lines due to its flexibility and low bending radius. Its braiding
screen creates protection against electromagnetical effects. Construction of
11YSLC11Y cable: Class 5 copper wire conductors insulated with TPU. Cores
are twisted in layers. Braiding of tinned copper wire. TPU jacket. RAL
7001 gray.
218-Y: British
Equivalent of harmonised H03VV-F cable. Flexible low voltage power cable.
Indoor appliance cable rated 300/300V.
2192Y: British
Equivalent of harmonised H03VVH2-F cable. Flexible Low voltage flat cable with undivisible cores.
2491B: British single core flexible Single core hook-up wire. Rated 300/500V.
Halogen free insulated Class5 Copper conductor. Maximum operating
temperature 900C. British equivalent of harmonised H05Z-K
2YSL11Y : Flexible, PE insulated
and TPU (Thermoplastic Polyurethane) sheathed instrumentation and low
voltage power cable. Produced according to VDE. 2YSL11Y cable is
used in instrument and control engineering, dry, moisture, oil, oil
derivatives and acidic environments in machine lines due to its flexibility
and low bending radius. TPU jacket creates extra protection
for chemicals. Construction of 2YSL11Y cable: Class 5 copper wire
conductors insulated with PE. Cores are twisted in layers. TPU jacket. RAL 7001
gray.
2YSL11YC11Y: Flexible, PE insulated and TPU ( Thermoplastic Polyurethane ) sheathed instrumentation and low voltage power cable. Produced according to VDE. 2YSL11YC11Y cable is used in instrument and control engineering, dry, moisture, oil, oil derivatives and acidic environments in machine lines due to its flexibility and low bending radius. Its braiding screen creates protection against electromagnetic interference while inner sheath of TPU creates extra protection against chemicals. Construction of 2YSL11YC11Y cable: Class 5 copper wire conductors insulated with PE. Cores are twisted in layers. Inner sheath of TPU over twisted cores. Braiding of tinned copper wire. TPU jacket. RAL 7001 gray.
2YSLC11Y: Flexible, PE insulated and TPU ( Thermoplastic Polyurethane ) sheathed instrumentation and low voltage power cable. Produced according to VDE. 2YSLC11Y cable is used in instrument and control engineering, dry, moisture, oil, oil derivatives and acidic environments in machine lines due to its flexibility and low bending radius. Also suitable as power cable for outdoor appliances. Its braiding screen creates protection against electromagnetical interference. Construction of 2YSLC11Y cable: Class 5 copper wire conductors insulated with PE. Cores are twisted in layers. Braiding of tinned copper wire. TPU jacket. RAL 7001 gray.
2YSLYC11Y: Flexible, PE insulated and TPU ( Thermoplastic Polyurethane ) jacketed instrumentation and low voltage power cable. Produced according to VDE. 2YSLYC11Y cable is used in instrument and control engineering, dry, moisture, oil, oil derivatives and acidic environments in machine lines due to its flexibility and low bending radius. Its braiding screen creates protection against electromagnetical effects while outer sheath of TPU creates extra protection for chemicals. Construction of 2YSLYC11Y cable: Class 5 copper wire conductors insulated with TPU. Cores are twisted in layers. Inner sheath of PVC compound over twisted cores. Braiding of tinned copper wire. TPU jacket. RAL 7001 gray.
309-Y: British equivalent of Harmonised H05V2V2-F cable
318-B: British equivalent of H05Z1Z1-F cable. Flexible low voltage power cable low smoke fume halogen free indoor cable. Rated 300/500V. Class 5 flexible fine copper Conductor , HF / HF construction.
318-Y: British equivalent of Harmonised H05VV-F cable
318-TRS British equivalent of H05RR-F cable. Rated 300/500V. Rubber insulation , rubber jacket multicore cable for flexible applications. Construction:Class5 flexible copper conductors, rubber insulated cores, rubber overall sheath.
6381TQ: Chlorosulphonated Polyethylene sheathed flexible cable. Design voltage 450/750 V. British equivalent of <HAR> H07BN4-F.
6491X: British flexible single core cable. Equivalent of H05V-K/ H07V-K.
6491B: British single core hook-up wire. Rated 450/750V. LSZH compound insulated Class 2 Copper conductor. Maximum operating temperature 90oC. Equivalent of Harmonised H07Z-R cable.
6701B: British flexible Single core hook-up wire. Rated 450/750V. Halogen free insulated Class5 Copper conductor. Maximum operating temperature 90oC. British Equivalent of harmonised H07Z-K.